Unit | Value | ||
---|---|---|---|
Light color | neutral-white | ||
Beam | 120° | ||
Height | 4.5mm | ||
Width | 8.0mm | ||
Length | 65.0mm | ||
Unit | min. | typ. | max. |
Lumen | 480lm | ||
Kelvin | 4000K | ||
Voltage | 8.7V | 8.7V | 10.5V |
Current | 350mA | 350mA |
Very cost efficiant LED module for constant current use @350mA.
Depending on the constant current power supply multiple modules can be driven in series connection, too. Easily connectable by using the onboard clamps with stare wires (with diamters from 0,2 up to 0,75mm²).
A heat conductive pad is included FOR FREE.
All modules of this series are assembled with the OSRAM Duris E5 in brightness bin "FU". If you need other bins or color temperatures please do not hesitate to contact us.
Features:
- Constant current use @350mA
- CRI >80
- Easy mounting and connectivity
- Heat conductive pad FOR FREE
Applications:
- mobile applications
- interior furnishing
- lamps
Successful usage of high power LEDs:
Heat management
Applications with high power LEDs need enduring, adequate and plane
heat conduction from the first moment of use. It is very important and
neccessary to get the heat off the devices to ensure the maximum light
output, lifetime and efficiancy.
Drive management
LEDs should be run with a constant current in addition to the
manufacturers recommendations. To ensure this we recommend to take
constant current power supplies because resistors are always a risk
factor in high power LED applications.
IP protection
Unless otherwise stated, the modules are not protected against high humidity or splashing water. If LEDs are used in areas that require increased protection, this must be manufactured according to the requirements.
EMC protection
LEDs are sensitive against heat and electric charge. Please avoid any
kind of short circuits or electric discharge to the illuminant. The chip
can be damaged or even destroyed.
Storage / JEDEC level
The storage temperature should be from -30°C up to + 80°C in dry
ambience. After opening a sealed bag the content should be mounted
rapidly. Once absorbed humidity can be removed by tempering the LEDs in
some cases. More information can be found in the manufacturers
datasheets or on the manufacturer homepages.
Soldering conditions
Each LED has its own soldering conditions that the user should pay
attention to. After the launched lead free processing specifications
many standarts have changed. Information about recommended soldering can
be found in the manufacturers datasheets or on the manufacturer
homepages.